品牌中杰特裝
型號(hào)CFL-20/2.16
類型低溫儲(chǔ)罐
材質(zhì)16MnDR
適用物料LCO2
常見(jiàn)故障的處理 Common fault handling
【產(chǎn)品詳情圖片】
1.內(nèi)罐壓力異常長(zhǎng)高 Inner tank pressure abnormally high
1.1可能是V3回氣閥開度過(guò)大或閥門失靈,應(yīng)減小閥門開度或檢修閥門。
May be V3 return valve opening is too large or valve failure, should reduce the valve opening or valve repair.
1.2可能是S1、S2安全閥失靈,到啟動(dòng)壓力不啟動(dòng),應(yīng)檢查安全閥。
may be S1, S2 safety valve failure, to start the pressure does not start, check the safety valve.
1.3可能是壓力表指示不準(zhǔn)確,應(yīng)校驗(yàn)壓力表。
may be pressure gauge indicates inaccurate, should verify the pressure gauge.
2.液位計(jì)指示不真實(shí) Level gauge instructions are not true
2.1可能是液位計(jì)失靈,應(yīng)檢修液位計(jì)。
may be the level gauge failure, should be maintenance level gauge
2.2可能是液位計(jì)接頭處泄漏,應(yīng)檢修接頭連接處,排除泄漏。
It may be a leak at the head of the liquid level gauge. It should repair the connection of the joint and eliminate the leakage
3.蒸發(fā)率高,外殼體凝水結(jié)霜 High evaporation rate, the outer shell condensate frost
3.1可能是珠光砂未填實(shí)或下沉,應(yīng)補(bǔ)充珠光砂,重新抽真空。
may be unfilled or sinking of pearl sand, pearl sand should be added and re-evacuated.
3.2可能是真空度惡化,應(yīng)進(jìn)行真空檢漏,重新抽真空。
may be a deterioration of the vacuum, vacuum leak detection should be carried out, re-vacuum.
4.管道閥門液體流動(dòng)不暢或堵塞 pipeline valve fluid flow or blocked
可能是液體二氧化碳形成干冰的原因造成,應(yīng)停止使用,用熱空氣加溫管閥至?xí)惩橹?。May be caused by the formation of dry ice, should stop using, with hot air heating pipe valve until smooth.
【產(chǎn)品詳情圖片】
【標(biāo)題】

低溫儲(chǔ)罐
低溫儲(chǔ)罐是用于存放液態(tài)氧、氮、氬、二氧化碳等介質(zhì)的立式或臥式雙層真空絕熱儲(chǔ)槽。內(nèi)膽選用材料為奧氏體不銹鋼;外容器材料根據(jù)用戶地區(qū)不同,按國(guó)家規(guī)定選用為Q235-B、Q245R或345R,內(nèi)、外容器夾層充填絕熱材料珠光砂或鋁箔、保溫棉并抽真空。
中文名 低溫儲(chǔ)罐 外文名 cryogenic storage tank 實(shí) 質(zhì) 立式或臥式雙層真空絕熱儲(chǔ)槽 結(jié) 構(gòu) 內(nèi)膽、隔熱層、外罐 填充材料 珠光砂或鋁箔、保溫棉 相關(guān)設(shè)備 常壓儲(chǔ)罐、常溫儲(chǔ)罐等。

1、操作前的準(zhǔn)備 Preparation before operation
【產(chǎn)品詳情圖片】
1.1 操作者應(yīng)按本說(shuō)明書要求及有關(guān)文件進(jìn)行操作。The operator shall follow the instructions and related documents to operate.
1.2正式投入使用前,用干燥的CO2氣體對(duì)整個(gè)系統(tǒng)進(jìn)行吹除置換,吹除置換所用的氣體純度不低于充裝介質(zhì)的純度。Formally put into use before the use of dry CO2 gas blowing the entire system replacement, purge replacement gas purity of not less than the purity of the filling
【產(chǎn)品詳情圖片】
【主變量】【變量3】【變量2】【變量1】

儲(chǔ)罐的增壓 Tank pressurization
【產(chǎn)品詳情圖片】
當(dāng)儲(chǔ)罐向外供液又需要穩(wěn)定排液壓力時(shí),可利用汽化器(另外配備)進(jìn)行增壓。其操作過(guò)程如下:
The carburetor (available separately) can be used for boosting when the reservoir is supplied externally and requires stable discharge pressure. The operation is as follows:
2.3.1開啟V2排液閥,使液體二氧化碳汽化器汽化,開啟V3回氣閥(根據(jù)用戶回氣管路的設(shè)置,V3回氣閥可置于常開狀態(tài))從汽化器分流出來(lái)的氣體返回儲(chǔ)罐上部,使儲(chǔ)罐內(nèi)增壓。
Open the V2 drain valve to vaporize the liquid carbon dioxide vaporizer and open the V3 return valve (the V3 return valve can be normally open depending on the return air line of the user). The gas diverted from the vaporizer returns to the upper part of the tank , So that the pressure tank.
2.3.2當(dāng)儲(chǔ)罐內(nèi)壓力達(dá)到2.1Mpa時(shí),可暫時(shí)關(guān)閉V3回氣閥。
When the tank pressure reaches 2.1Mpa, the valve can be temporarily closed V3 return gas valve.
2.3.3排液過(guò)程中,可通過(guò)控制V3回氣閥的開度,使增壓能力維持在壓力穩(wěn)定的水平。
During drainage, the degree of pressurization can be maintained at a pressure-stable level by controlling the opening of the V3 return valve.
【產(chǎn)品詳情圖片】