品牌中杰特裝
型號(hào)CFL-20/2.16
類型低溫儲(chǔ)罐
材質(zhì)16MnDR
適用物料LCO2
液體的儲(chǔ)存 liquid storage
液體二氧化碳的儲(chǔ)存屬于帶壓(壓力不低于0.8Mpa)儲(chǔ)存。儲(chǔ)存期間除壓力表、液位計(jì)、安全閥應(yīng)投入使用外,其他閥門應(yīng)處于關(guān)閉狀態(tài)。當(dāng)儲(chǔ)罐壓力超過(guò)2.1Mpa時(shí),開(kāi)啟V7排氣閥降壓。但應(yīng)注意:內(nèi)罐的壓力不得降至低于0.8Mpa,否則將引起液體二氧化碳轉(zhuǎn)變?yōu)楦杀?br>Liquid carbon dioxide storage with pressure (pressure not less than 0.8Mpa) storage. During the storage, the pressure gauge,level gauge, safety valve should be put into use, the other valves should be closed. When the tank pressure exceeds 2.1Mpa, open the V7 exhaust valve buck. However, it should be noted that the pressure inside the tank must not drop below 0.8Mpa, otherwise liquid carbon dioxide will be converted to dry ice.
【產(chǎn)品詳情圖片】
【標(biāo)題】

注意事項(xiàng)matters need attention
在您購(gòu)買我公司的設(shè)備之際,請(qǐng)接收我們誠(chéng)摯的謝意。我們嚴(yán)格按標(biāo)準(zhǔn)和工藝進(jìn)行制造,但由于安裝和使用的不當(dāng),仍會(huì)引起意外事故。本使用說(shuō)明書(shū)所示安全事項(xiàng)是為了您能安全正確的使用本設(shè)備,防止您或他人的危害或損害于未然,一旦實(shí)施錯(cuò)誤的操作方法,其產(chǎn)生的后果均與安全有關(guān)。請(qǐng)接受本使用說(shuō)明書(shū)的指導(dǎo),并注意如下事項(xiàng):
Please receive our sincere thanks for your purchase of our equipments. We manufacture in strict accordance with standards and craftsmanship, but will still cause accidents due to improper installation and use. The safety instructions in this manual are for the purpose of safe and correct use of this equipment, to prevent the harm to you or others from harm or damage, and once the wrong operation method is implemented, all the consequences arising therefrom are safety related. Please accept the instructions in this manual, and note the following:
1本設(shè)備屬于特種設(shè)備,要設(shè)專職人員管理與操作,操作人員要經(jīng)過(guò)培訓(xùn)持證上崗,否則由于誤操作和使用,會(huì)造成危及生命安全的可能。
The equipment belongs to special equipment, which should be managed and operated by full-time personnel. Operators should be trained and certified to be on duty. Otherwise, it will be possible to endanger life safety due to misoperation and use.
2 本設(shè)備的安裝、使用及維修應(yīng)符合JB6898-1997《低溫液體貯運(yùn)設(shè)備 使用安全規(guī)則》的規(guī)定。本設(shè)備應(yīng)放在室外、通風(fēng)良好的場(chǎng)所。CO2有很強(qiáng)的窒息性,會(huì)引起窒息危險(xiǎn),甚至危及生命。
the installation, use and maintenance of the equipment shall conform to the provisions of JB6898-1997 "safe rules for the use of cryogenic liquid storage and transportation equipment". The equipment should be placed outdoors and well ventilated. CO2 has a strong asphyxiation, which can cause choking hazards and even life.
3 本設(shè)備貯存的是-40℃的低溫液體,管道、閥門凍結(jié)堵塞時(shí)嚴(yán)禁用重物敲擊、火烤或冷水噴淋等方法解凍,應(yīng)用70~80℃干凈無(wú)油的熱空氣、熱氮?dú)饨鈨觥?br>this equipment is to 40 ℃ cryogenic liquid storage, pipe, valves, frozen jams it is forbidden to use heavy percussion, fire, or cold water spray method of thawing, application of 70 ~ 80 ℃ clean hot air, hot nitrogen release without oil.
【產(chǎn)品詳情圖片】
【變量3】【變量2】【變量1】

維護(hù)與檢修 Maintenance and repair
【產(chǎn)品詳情圖片】
1.儲(chǔ)罐的使用與維護(hù),應(yīng)按“壓力容器安全技術(shù)監(jiān)察規(guī)程”要求和本說(shuō)明進(jìn)行。
The use and maintenance of the storage tank shall be carried out according to the requirements of the Pressure Vessel Safety Technical Supervision Regulations and these instructions
2.日常檢查與維護(hù) Daily inspection and maintenance
儲(chǔ)罐在運(yùn)行過(guò)程中,要經(jīng)常檢查安全閥、壓力表、液位計(jì)工作是否正常,閥門管路是否有泄漏,外部有無(wú)異?,F(xiàn)象,發(fā)現(xiàn)問(wèn)題及時(shí)處理。
During operation of the tank, check the safety valve, pressure gauge and liquid level meter regularly, whether the valve line is leaking, whether there is any abnormal phenomenon outside, and find the problem to be handled in time.
3.定期校驗(yàn) Regular verification
3.1安全閥整定壓力不大于2.27Mpa,每年至少校驗(yàn)一次,并加鉛封,作好記錄。
Safety valve setting pressure is not more than 2.27Mpa, at least once a year, and add seals, make a record.
3.2定期檢查夾層真空度,未裝低溫介質(zhì)的情況下真空度應(yīng)低于65Pa,裝有低溫介質(zhì)的情況下,真空度應(yīng)低于10Pa為合格。
Regularly check the sandwich vacuum, the vacuum should be less then 65Pa without vacuum medium; with a low temperature medium, the vacuum should be less than 10Pa for the pass.
【產(chǎn)品詳情圖片】
【標(biāo)題】

常見(jiàn)故障的處理 Common fault handling
【產(chǎn)品詳情圖片】
1.內(nèi)罐壓力異常長(zhǎng)高 Inner tank pressure abnormally high
1.1可能是V3回氣閥開(kāi)度過(guò)大或閥門失靈,應(yīng)減小閥門開(kāi)度或檢修閥門。
May be V3 return valve opening is too large or valve failure, should reduce the valve opening or valve repair.
1.2可能是S1、S2安全閥失靈,到啟動(dòng)壓力不啟動(dòng),應(yīng)檢查安全閥。
may be S1, S2 safety valve failure, to start the pressure does not start, check the safety valve.
1.3可能是壓力表指示不準(zhǔn)確,應(yīng)校驗(yàn)壓力表。
may be pressure gauge indicates inaccurate, should verify the pressure gauge.
2.液位計(jì)指示不真實(shí) Level gauge instructions are not true
2.1可能是液位計(jì)失靈,應(yīng)檢修液位計(jì)。
may be the level gauge failure, should be maintenance level gauge
2.2可能是液位計(jì)接頭處泄漏,應(yīng)檢修接頭連接處,排除泄漏。
It may be a leak at the head of the liquid level gauge. It should repair the connection of the joint and eliminate the leakage
3.蒸發(fā)率高,外殼體凝水結(jié)霜 High evaporation rate, the outer shell condensate frost
3.1可能是珠光砂未填實(shí)或下沉,應(yīng)補(bǔ)充珠光砂,重新抽真空。
may be unfilled or sinking of pearl sand, pearl sand should be added and re-evacuated.
3.2可能是真空度惡化,應(yīng)進(jìn)行真空檢漏,重新抽真空。
may be a deterioration of the vacuum, vacuum leak detection should be carried out, re-vacuum.
4.管道閥門液體流動(dòng)不暢或堵塞 pipeline valve fluid flow or blocked
可能是液體二氧化碳形成干冰的原因造成,應(yīng)停止使用,用熱空氣加溫管閥至?xí)惩橹埂ay be caused by the formation of dry ice, should stop using, with hot air heating pipe valve until smooth.