品牌中杰特裝
型號CFL-20/2.16
類型低溫儲罐
材質(zhì)16MnDR
適用物料LCO2
充液的操作 filling operation
【標題】
充液分為充液和補充充液。
充液的操作如下:
Filling fluid is divided into the first filling and filling fluid.
The first filling operation is as follows:
2.1.1 儲罐吹除置換干凈達到要求后,將充液管線與儲罐的充液接頭連接,液位計組合閥處于平衡狀態(tài)準備充液。
After the tank blows off to replace the cleanliness meets the requirements, the filling liquid line is connected with the liquid filling joint of the tank, and the liquid level gauge combination valve is in an equilibrium state to be filled.
2.1.2充入與液體二氧化碳純度相同的氣體,使罐內(nèi)壓力達到0.8 Mpa以上,方可進行充液。 filled with the same purity of liquid carbon dioxide gas, the tank pressure reached 0.8 Mpa above, before filling.
2.1.3 將充液管線接通槽車,先開啟V5殘液閥,排出管線內(nèi)的雜質(zhì)氣體后,再開啟V1進液閥和V7排氣閥,V8液位計組合閥處于全開狀態(tài),顯示液位計讀數(shù)進行充液。
The filling liquid line connected tanker, first open the V5 raffinate valve, exhaust gas impurities within the pipeline, and then open the V1 inlet valve and V7 exhaust valve, V8 level gauge combination valve is fully open state, Display level meter readings are filled.
2.1.4 在充液過程中,當液位計指示液位接近標定值時,可間斷開啟V4充滿指示閥,如有液體噴出,應(yīng)立即停止充液,關(guān)閉V4充滿指示閥。
During the filling process, when the liquid level gauge indicates the liquid level approaches the calibration value, the V4 may be intermittently opened to indicate the valve. If any liquid is ejected, liquid filling should be stopped immediately and the V4 valve should be closed.
2.1.5關(guān)閉V1進液閥和V7排氣閥,打開V5殘液閥,拆下充液管線,充液結(jié)束。
補充充液的操作與充液的操作方法相似,不同點是補充充液時一開始就可以大量充液。
Close the V1 inlet valve and the V7 exhaust valve, open the V5 residual valve, remove the filling line, and fill with liquid.
The procedure for replenishing the priming solution is the same as for the first priming procedure, except that the priming solution can be replenished extensively from the beginning.
【產(chǎn)品詳情圖片】
【標題】

常見故障的處理 Common fault handling
【產(chǎn)品詳情圖片】
1.內(nèi)罐壓力異常長高 Inner tank pressure abnormally high
1.1可能是V3回氣閥開度過大或閥門失靈,應(yīng)減小閥門開度或檢修閥門。
May be V3 return valve opening is too large or valve failure, should reduce the valve opening or valve repair.
1.2可能是S1、S2安全閥失靈,到啟動壓力不啟動,應(yīng)檢查安全閥。
may be S1, S2 safety valve failure, to start the pressure does not start, check the safety valve.
1.3可能是壓力表指示不準確,應(yīng)校驗壓力表。
may be pressure gauge indicates inaccurate, should verify the pressure gauge.
2.液位計指示不真實 Level gauge instructions are not true
2.1可能是液位計失靈,應(yīng)檢修液位計。
may be the level gauge failure, should be maintenance level gauge
2.2可能是液位計接頭處泄漏,應(yīng)檢修接頭連接處,排除泄漏。
It may be a leak at the head of the liquid level gauge. It should repair the connection of the joint and eliminate the leakage
3.蒸發(fā)率高,外殼體凝水結(jié)霜 High evaporation rate, the outer shell condensate frost
3.1可能是珠光砂未填實或下沉,應(yīng)補充珠光砂,重新抽真空。
may be unfilled or sinking of pearl sand, pearl sand should be added and re-evacuated.
3.2可能是真空度惡化,應(yīng)進行真空檢漏,重新抽真空。
may be a deterioration of the vacuum, vacuum leak detection should be carried out, re-vacuum.
4.管道閥門液體流動不暢或堵塞 pipeline valve fluid flow or blocked
可能是液體二氧化碳形成干冰的原因造成,應(yīng)停止使用,用熱空氣加溫管閥至暢通為止。May be caused by the formation of dry ice, should stop using, with hot air heating pipe valve until smooth.
【產(chǎn)品詳情圖片】
【標題】

注意事項matters need attention
在您購買我公司的設(shè)備之際,請接收我們誠摯的謝意。我們嚴格按標準和工藝進行制造,但由于安裝和使用的不當,仍會引起意外事故。本使用說明書所示安全事項是為了您能安全正確的使用本設(shè)備,防止您或他人的危害或損害于未然,一旦實施錯誤的操作方法,其產(chǎn)生的后果均與安全有關(guān)。請接受本使用說明書的指導,并注意如下事項:
Please receive our sincere thanks for your purchase of our equipments. We manufacture in strict accordance with standards and craftsmanship, but will still cause accidents due to improper installation and use. The safety instructions in this manual are for the purpose of safe and correct use of this equipment, to prevent the harm to you or others from harm or damage, and once the wrong operation method is implemented, all the consequences arising therefrom are safety related. Please accept the instructions in this manual, and note the following:
1本設(shè)備屬于特種設(shè)備,要設(shè)專職人員管理與操作,操作人員要經(jīng)過培訓持證上崗,否則由于誤操作和使用,會造成危及生命安全的可能。
The equipment belongs to special equipment, which should be managed and operated by full-time personnel. Operators should be trained and certified to be on duty. Otherwise, it will be possible to endanger life safety due to misoperation and use.
2 本設(shè)備的安裝、使用及維修應(yīng)符合JB6898-1997《低溫液體貯運設(shè)備 使用安全規(guī)則》的規(guī)定。本設(shè)備應(yīng)放在室外、通風良好的場所。CO2有很強的窒息性,會引起窒息危險,甚至危及生命。
the installation, use and maintenance of the equipment shall conform to the provisions of JB6898-1997 "safe rules for the use of cryogenic liquid storage and transportation equipment". The equipment should be placed outdoors and well ventilated. CO2 has a strong asphyxiation, which can cause choking hazards and even life.
3 本設(shè)備貯存的是-40℃的低溫液體,管道、閥門凍結(jié)堵塞時嚴禁用重物敲擊、火烤或冷水噴淋等方法解凍,應(yīng)用70~80℃干凈無油的熱空氣、熱氮氣解凍。
this equipment is to 40 ℃ cryogenic liquid storage, pipe, valves, frozen jams it is forbidden to use heavy percussion, fire, or cold water spray method of thawing, application of 70 ~ 80 ℃ clean hot air, hot nitrogen release without oil.
【產(chǎn)品詳情圖片】
【變量3】【變量2】【變量1】

結(jié)構(gòu)說明 Structure Description
1. 泄放裝置 Discharge device
2. 內(nèi)膽 Liner
3.保溫層(珠光砂) Insulation (pear sand)
4.外殼 Shell
5.儀表(差壓計、氧壓表、組合閥) Meter (differential pressure gauge, oxygen pressure gauge, combination valve)
6.抽空口及真空閥門Evacuation port and vacuum valve
7.管路閥門 Pipeline Valve
說 明Description:
⑴本儲罐的操作系統(tǒng)多集中于儲罐底部,儀表系統(tǒng)及組合閥設(shè)置在筒壁,便于觀察操作.
The operating system of the tank and more concentrated in the bottom of the tank, instrument system and valve combination set in the cylinder wall, easy to observe the operation.
(2) 內(nèi)膽設(shè)置有兩個安全閥S1、S2,夾層泄壓裝置B。
There are two safety valves S1, S2 inside the liner, sandwich pressure relief device B.
(3) 連接形式:進液口→2"螺紋連接,排液閥→2"螺紋連接,抽空口→法蘭.
Connection: inlet → 2 "thread connection, drain valve → 2" thread connection, exhaust port → flange.
【產(chǎn)品詳情圖片】